EMC offers a complete line of Hazmat Decon equipment as well as portable showers and shelters.
EMERGENCY
SHELTERS FOR HAZMAT AND DECON

The AIRSHELTER III, IV and V offer complete protection and is easy to set up (2 minutes) using a portable air blower or SCBA cylinder.
The shelters are available in 10 x 12, 15 x 19 and 19 x 27
INCLUDES:
Tightening belts
Heater/AC hook-up sleeves
Skylight in roof
Provision for aerial identification
FEATURES:
Lightweight - one man setup
Airframe design allows for automatic deployment
Separate pressure chambers in frame
Large doorway - can attach to vehicle
Built-in safety valves
Ample headroom
Stays up for several days without re-inflation
|

SETS UP IN
2 MINUTES
|

SCBA CYLINDER
|
|

BLOWER
|
OPTIONS:
INTEGRATED WATER BELTS FOR ANCHORING
10 CM HIGH WATERPROOF FLOOR WINDOWS
THERMAL ISOLATION INNER LINER
EXTERNAL TENT HEATER
MASS DECON
101

MASS DECON 101: Mass decontamination shower system. Capable of decontamination of multiple persons quickly and efficiently. This system offers a
complete shelter with integrated dual shower cabins. The shelter is designed for two persons to simultaneously
enter the shelter into a curtained area for undress. Then proceed into the Shower
cabin for decontamination and exit into a curtained area for redress. Decontamination
can take place at 30 seconds per person in cases of mass casualty. There is also
ample space for decontamination of persons lying on stretchers. The Airshelter
concept is ideal for providing shelter during harsh weather conditions. The
shelter can be equipped with an optional heating unit and lighting kits. The shelter is erected by using an SCBA cylinder or air pump. The shelters tubular airframe is equipped with a built in pressure valve to prevent over pressurization.
System Operation:
The MASS DECON 101 shelter is erected in under two minutes with either SCBA cylinders and a regulator or an electric air pump. A water hose is fed to the Hydrophor pump which maintains a constant 50 psi on-demand pressure. The water is then feed to the Hotbox which is electric and Diesel operated. The hotbox is an on-demand hot water system. The hot water can be passed through a solvent/detergent inducer and then back into a 4 point manifold on the hotbox. Two hoses feed the two showers in the tent and two hoses with pistol grips are used for prewash. A waste water transfer pump is connected to the outlet from the shower. This pump removes the contaminated water from the shower basin and pumps it into a collapsible waste fluid container. The waste fluid container uses a replaceable liner and includes a shutoff valve for pump out. Optional heating and lighting kits are available. Complete system includes:
AIRSHELTER III - 19 L x 15 W x 9 H
16 Tent anchor stakes
Fully integrated (removable) Dual Shower Cabin
15 hose (water supply to Hydrophor Pump)
Hydrophor Pump supplies on-demand water
30 ( Hydrophor Pump to Hotbox 200)
Hotbox 200 provides on-demand hot water
Two 18 hoses (Hotbox to Showers)
Two 18 hoses with pistol grip (hotbox to shower area)
Detergent Inducer
Two 41/2 hoses (hotbox to inducer - inducer to hotbox)
Waste water transfer pump
3 hose (shower cabin to waste water pump)
30 hose (waste water pump to waste fluid container)
Liner for waste fluid container
Shutoff valve for waste fluid container
MASS DECON
102 is an identical system with the larger AIRSHELTER IV - 27 L x 19 W x 9 H
HAZMAT DECON SYSTEMS
For HAZMAT Decontamination
Canadian Safety offers all the components to put together a complete Decon system including a Decon Shower and basin, Decon Cabin and portable water heaters, pumps, detergent/solvent inducers, waste water transfer pumps, fluid bags etc.
|
|
The HYDROPHOR pump is automatically activated
when a shower valve is turned on and will maintain a constant flow. Shut off is also automatic when valves
are turned off. The water supply is connected to the HYDROPHOR pump and all flows and pressures are
controlled by the pump. |
|
|
The HOTBOX on-demand water
heater supplies instantaneous temperature controlled hot water to the shower. The solvent
inducer can be directly attached to control solvent/detergent
addition. |
|
|
Submergible WASTE WATER TRANSFER pump can be placed
iinside the basin or connected through a valve to transfer the waste water to a fluid bag for
storage and removal. |
|
|
Lightweight FLUID BAG folds
flat when not in use and when unfolded holds up to 125 gallons
of waste water. It can also be used as a reservoir to hold fresh water for the shower. An
optional shut-off valve can be used to transfer water to smaller
containers. Four heavy duty lifting straps are included. |
|
|
A three layer polyethylene liner
with two threaded fittings is available for the fluid bag. |

If you would like for information on the complete
line of Equipment Management Company please go to our Info
Request page.
Visit
EMC's Web Site
MANUFACTURERS
| LOCATION MAP | WHAT'S NEW |
ARTICLES
TRADE SHOWS | INFO REQUEST |
EQUIPMENT FOR SALE
CANADIAN SAFETY EQUIPMENT
INC.
Tel:(905) 949-2741 or 1-800-265-0182
Fax:(905) 272-1866
2465 Cawthra Road, Unit 114 ( Directions to our
building )
Mississauga, Ontario, Canada L5A 3P2
e-mail: info@cdnsafety.com
Copyright © 1997-2010, Canadian Safety Equipment Inc. All rights reserved.
Design and Maintenance by
Webstar
Solutions
Updated: August 12, 2010
|